Gicam weight indicators are weight indicator devices connected to load cells. We have multifunction displayers for weighing and dosing, for bridge weighing, with load limiter. Portable displayers are available in comfortable briefcases. We have panel mounting, portable, DIN and OMEGA bar mounts, analog indicators and touch screens indicators. IP65 products are available with dust protection. Gicam indicators support industrial communication protocols like PROFIBUS, PROFINET, MODBUS and more.
Digital AMPLIFIER with CANOPEN interface
Click to enlarge image
Power supply | 24 V direct current ± 10% protected against polarity inversion, protection with resettable fuse | |
Max power consumption | 2 W | |
Isolation | Class II | |
Installation Category | Category II | |
Operating temperature | -10 / +50 °C (14 / 122 °F) Humidity Maximum 85% non-condensing | |
Storage temperature | -10 / +60°C (-4 / +140°F) | |
Display | Numeric with 5 red led digits 7 segments each (h 7 mm) | |
Led | 2 LED with 3 mm | |
Keyboard | 3 keys (behind red front cover) | |
Overall dimensions | 110 mm x 120 mm x 35 mm / 4.33 x 4.72 x 1.38 in (l x h x p) | |
Mounting | Support for DIN rail or OMEGA bar | |
Case material | Blend ABS/PC self-extinguishing | |
Connections | Removable screw terminals. Pitch screws terminal blocks 5.08 mm | |
Load cell input features | Maximum 4 cells with 350 Ω in parallel (or 8 cells with 700 Ω) | |
Power supply load cells | 4 V | |
Linearity | < 0.01% of full scale | |
Temperature deviation | < 0.001% of full scale/C° | |
Internal resolution | 24 bit | |
Measuring range | From -2.6 mV/V to +2.6 mV/V | |
Output rate | From 4 Hz to 123 Hz | |
Number of weight decimals | From 0 to 3 decimals | |
Zero / FS Calibration | Executable through buttons | |
Cell cable interruption check | Always present | |
Serial port | Rs232 half duplex | |
Max. cable length | 15 m (Rs232c) 49 ft (RS232c) | |
Baud rate | 1200, 2400, 4800, 9600, 19200, 38400, 115200 | |
Field bus | CANOpen - Baud Rate 20, 50, 125, 250, 500, 800 kb/sec, 1 Mb/sec | |
Conforms to standards | Compliance to EMC norms: EN61000-6-2, EN61000-6-3, Compliance electric safety: EN 61010-1 |
General precautions to be followed in the installation and assembly of load cells: